CDS OM‐01041‐08November 6, 1996Rev. K 02‐26‐13THE GORMAN‐RUPP COMPANY MANSFIELD, OHIOwww.grpumps.comGORMAN‐RUPP OF CANADA LIMITED ST. THOMAS,
OM-01041T SERIESPAGE B - 3INSTALLATIONcompatible with the liquid being pumped. If hose isused in suction lines, it must be the rigid‐wall, reinforced
OM-01041 T SERIESPAGE B - 4 INSTALLATIONIf it is necessary to position inflow close to the suction inlet, install a baffle between the inflow and the
OM-01041T SERIESPAGE B - 5INSTALLATIONIf the application involves a high dischargehead, gradually close the dischargethrottling valve before stopping
OM-01041 T SERIESPAGE B - 6 INSTALLATIONmoving the plug to prevent injury to personnel from hot liquid.AUTOMATIC AIR RELEASE VALVEWhen properly insta
OM-01041T SERIESPAGE B - 7INSTALLATIONALIGNMENTThe alignment of the pump and its power source iscritical for trouble‐free mechanical operation. Ineith
OM-01041 T SERIESPAGE B - 8 INSTALLATIONtems using two or more belts, make certain that thebelts are a matched set; unmatched sets will causeaccelerat
T SERIESOM-01041OPERATION PAGE C - 1OPERATION - SECTION CReview all SAFETY information in Section A.Follow the instructions on all tags, labels and de
T SERIESOM-01041OPERATIONPAGE C - 2If rotation is incorrect on a three‐phase motor, havea qualified electrician interchange any two of thethree phase
T SERIESOM-01041OPERATION PAGE C - 3valve with a substitute which has not been specified or provided by the Gorman‐Rupp Company.Strainer CheckIf a su
T SERIESOM-01041OPERATIONPAGE C - 4against the housing. Record this temperature forfuture reference.A sudden increase in bearing temperature is awarni
Register your newGorman‐Rupp pump online atwww.grpumps.comValid serial number and e‐mail address required.RECORD YOUR PUMP MODEL AND SERIAL NUMBERPlea
T SERIES OM-01041TROUBLESHOOTING PAGE D - 1TROUBLESHOOTING - SECTION DReview all SAFETY information in Section A.Before attempting to open or service
OM-01041T SERIESTROUBLESHOOTINGPAGE D - 2TROUBLE POSSIBLE CAUSE PROBABLE REMEDYPUMP REQUIRESTOO MUCHPOWERPUMP CLOGSFREQUENTLYImpeller or other wearing
T SERIES OM-01041TROUBLESHOOTING PAGE D - 3TROUBLE POSSIBLE CAUSE PROBABLE REMEDYBEARINGS RUNTOO HOTBearing temperature is high, butwithin limits.Chec
OM-01041T SERIESTROUBLESHOOTINGPAGE D - 4General Condition (Temperature, UnusualNoises or Vibrations, Cracks, Leaks,Loose Hardware, Etc.) IPump Perfor
OM-01041T SERIESMAINTENANCE & REPAIR PAGE E - 1PUMP MAINTENANCE AND REPAIR - SECTION EMAINTENANCE AND REPAIR OF THE WEARING PARTS OF THE PUMP WILL
OM-01041 T SERIESMAINTENANCE & REPAIRPAGE E - 2SECTION DRAWINGPARTS PAGEFigure 1. Pump Model T3A3-B, Including /F, /FM
ITEM NO.PART NAME PART NUMBERMAT'LCODEQTY ITEM NO.PART NAME PART NUMBERMAT'LCODEQTYOM-01041T SERIESMAINTENANCE & REPAIR PAGE E - 3PARTS
OM-01041 T SERIESMAINTENANCE & REPAIRPAGE E - 4SECTION DRAWINGDRIVE END VIEWSEAL AREA DETAILFigure 2. 44163-219 Repair Rotating Assembly
ITEM NO.PART NAME PART NUMBERMAT'LCODEQTY ITEM NO.PART NAME PART NUMBERMAT'LCODEQTYOM-01041T SERIESMAINTENANCE & REPAIR PAGE E - 5PARTS
OM-01041 T SERIESMAINTENANCE & REPAIRPAGE E - 6PUMP AND SEAL DISASSEMBLYAND REASSEMBLYReview all SAFETY information in Section A.Follow the instru
TABLE OF CONTENTSiINTRODUCTION PAGE I - 1...SAFETY - SECTION A PAGE A - 1...
OM-01041T SERIESMAINTENANCE & REPAIR PAGE E - 7back cover opening and pull the complete assembly from the suction flange (26).NOTEFurther disasse
OM-01041 T SERIESMAINTENANCE & REPAIRPAGE E - 8length of pipe into the vent hole until fully engaged.Install the tee, and screw the handles into t
OM-01041T SERIESMAINTENANCE & REPAIR PAGE E - 9Clean the bearings thoroughly in fresh cleaningsolvent. Dry the bearings with filtered compressedai
OM-01041 T SERIESMAINTENANCE & REPAIRPAGE E - 10If heating the bearings is not practical, use a suitable sized sleeve, and an arbor (or hydraulic
OM-01041T SERIESMAINTENANCE & REPAIR PAGE E - 11SEAL PLATEO‐RINGSIMPELLERSHAFTSTATIONARYSEATSTATIONARYELEMENTROTATINGELEMENTDRIVE BANDBELLOWSIMPEL
OM-01041 T SERIESMAINTENANCE & REPAIRPAGE E - 12O‐RING ENGAGEDWITH SEAL PLATEBORESHEAR RING(UNSHEARED)Figure 6. Seal Partially InstalledContinue
OM-01041T SERIESMAINTENANCE & REPAIR PAGE E - 13Slide the rotating portion of the seal (consisting ofthe integral shaft sleeve, spring centering w
OM-01041 T SERIESMAINTENANCE & REPAIRPAGE E - 14and measure the gap. Add or subtract rotating assembly shims accordingly.Suction Check Valve Inst
OM-01041T SERIESMAINTENANCE & REPAIR PAGE E - 15Be sure the pump and power source have beenproperly lubricated, see LUBRICATION.Remove the fill co
For U.S. and International Warranty Information,Please Visit www.grpumps.com/warrantyor call:U.S.: 419-755-1280International: +1-419-755-1352For Canad
TABLE OF CONTENTS(continued)iiTROUBLESHOOTING - SECTION D PAGE D - 1...PREVENTIVE MAINTENANCE PAGE D - 3...
T SERIES OM-01041PAGE I - 1INTRODUCTIONINTRODUCTIONThank You for purchasing a Gorman‐Rupp pump.Read this manual carefully to learn how to safelyinstal
T SERIES OM-01041PAGE A - 1SAFETYSAFETY - SECTION AThis information applies to T Series basic pumps. Gorman‐Rupp has no control over or particular k
T SERIESOM-01041PAGE A - 2 SAFETYcharge valve, pump components willdeteriorate, and the liquid could cometo a boil, build pressure, and cause thepump
OM-01041T SERIESPAGE B - 1INSTALLATIONINSTALLATION - SECTION BReview all SAFETY information in Section A.Since pump installations are seldom identical
OM-01041 T SERIESPAGE B - 2 INSTALLATIONPREINSTALLATION INSPECTIONThe pump assembly was inspected and tested before shipment from the factory. Before