CDS OM‐05444-OB01October 30, 2002Rev. B 04‐23‐13THE GORMAN‐RUPP COMPANY MANSFIELD, OHIOwww.grpumps.comGORMAN‐RUPP OF CANADA LIMITED ST. THOMAS, O
OM-05444SUPER T SERIESPAGE B - 3INSTALLATIONLines near the pump must be independently supported to avoid strain on the pump which couldcause excessiv
OM-05444 SUPER T SERIESPAGE B - 4 INSTALLATIONNOTEThe pipe submergence required may be reducedby installing a standard pipe increaser fitting at thee
OM-05444SUPER T SERIESPAGE B - 5INSTALLATIONDo Not install a manual shut‐off valve in a bypassline. If a manual shut‐off valve is installed to facili
OM-05444 SUPER T SERIESPAGE B - 6 INSTALLATIONSome leakage (1 to 5 gallons [3.8 to 19liters] per minute) will occur when thevalve is fully closed. Be
OM-05444SUPER T SERIESPAGE B - 7INSTALLATIONpump and piping are installed, and before operation.NOTECheck Rotation, Section C, before final alignment
OM-05444 SUPER T SERIESPAGE B - 8 INSTALLATIONMISALIGNED:SHAFTSNOT PARALLELMISALIGNED:SHAFTSNOT IN LINEALIGNED: SHAFTSPARALLEL ANDSHEAVES IN LINEFigur
SUPER T SERIESOM-05444OPERATION PAGE C - 1OPERATION - SECTION CReview all SAFETY information in Section A.Follow the instructions on all tags, labels
SUPER T SERIESOM-05444OPERATIONPAGE C - 2reading on the discharge pressure gauge or by aquieter operation. The pump may not prime immediately because
SUPER T SERIESOM-05444OPERATION PAGE C - 3Shut off the pump. The vacuum gauge reading willimmediately drop proportionate to static suctionlift, and sh
OM-05444SUPER T SERIESTROUBLESHOOTING PAGE D - 1TROUBLESHOOTING - SECTION DReview all SAFETY information in Section A.Before attempting to open or ser
Register your newGorman‐Rupp pump online atwww.grpumps.comValid serial number and e‐mail address required.RECORD YOUR PUMP MODEL AND SERIAL NUMBERPlea
OM-05444 SUPER T SERIESTROUBLESHOOTINGPAGE D - 2Table 1. Trouble Shooting Chart (cont.)TROUBLE POSSIBLE CAUSE PROBABLE REMEDYPUMP STOPS OR FAILSTO DEL
OM-05444SUPER T SERIESTROUBLESHOOTING PAGE D - 3Table 1. Trouble Shooting Chart (cont.)TROUBLEPOSSIBLE CAUSE PROBABLE REMEDYBEARINGS RUN TOOHOTBearing
OM-05444 SUPER T SERIESTROUBLESHOOTINGPAGE D - 4General Condition (Temperature, UnusualNoises or Vibrations, Cracks, Leaks,Loose Hardware, Etc.) IPump
OM-05444SUPER T SERIESMAINTENANCE & REPAIR PAGE E - 1PUMP MAINTENANCE AND REPAIR - SECTION EMAINTENANCE AND REPAIR OF THE WEARING PARTS OF THE PUM
OM-05444 SUPER T SERIESMAINTENANCE & REPAIRPAGE E - 2SECTION DRAWINGPARTS PAGEFigure E-1. Pump Model T10A61S-B, /FM
ITEM NO.PART NAME PART NUMBERMAT'LCODEQTY ITEM NO.PART NAME PART NUMBERMAT'LCODEQTYOM-05444SUPER T SERIESMAINTENANCE & REPAIR PAGE E - 3
OM-05444 SUPER T SERIESMAINTENANCE & REPAIRPAGE E - 4SECTION DRAWINGDRIVE END VIEWFigure E‐2. 44163-351 Repair Rotating Assembly
ITEM NO.PART NAME PART NUMBERMAT'LCODEQTY ITEM NO.PART NAME PART NUMBERMAT'LCODEQTYOM-05444SUPER T SERIESMAINTENANCE & REPAIR PAGE E - 5
OM-05444 SUPER T SERIESMAINTENANCE & REPAIRPAGE E - 6PUMP AND SEAL DISASSEMBLYAND REASSEMBLYReview all SAFETY information in Section A.Follow the
OM-05444SUPER T SERIESMAINTENANCE & REPAIR PAGE E - 7Suction Head And Wear Plate Removal(Figure E‐1)To remove the suction head, support it with a
TABLE OF CONTENTSiINTRODUCTION PAGE I - 1...SAFETY - SECTION A PAGE A - 1...
OM-05444 SUPER T SERIESMAINTENANCE & REPAIRPAGE E - 8ADD PIPEAS REQUIREDFigure E‐3. Rotating Assembly Removal With ToolImpeller Removal(Figure E‐2
OM-05444SUPER T SERIESMAINTENANCE & REPAIR PAGE E - 9After removing the shaft and bearings, clean andinspect the bearings in place as follows.To p
OM-05444 SUPER T SERIESMAINTENANCE & REPAIRPAGE E - 10NOTEIf a hot oil bath is used to heat the bearings, both theoil and the container must be ab
OM-05444SUPER T SERIESMAINTENANCE & REPAIR PAGE E - 11the bearing bore, push against the outerrace. Never hit the balls or ball cage.Position the
OM-05444 SUPER T SERIESMAINTENANCE & REPAIRPAGE E - 12SEAL PLATEO‐RINGSIMPELLERSHAFTSTATIONARYSEATSTATIONARYELEMENTROTATINGELEMENTDRIVE BANDBELLOW
OM-05444SUPER T SERIESMAINTENANCE & REPAIR PAGE E - 13any time the old seal is removed from thepump. Wear patterns on the finished facescannot be
OM-05444 SUPER T SERIESMAINTENANCE & REPAIRPAGE E - 14Rotating Assembly Installation(Figure E‐1)Install the bearing housing and seal plate O‐rings
OM-05444SUPER T SERIESMAINTENANCE & REPAIR PAGE E - 15been specified or provided by the Gorman‐RuppCompany.Periodically, the valve should be remov
For U.S. and International Warranty Information,Please Visit www.grpumps.com/warrantyor call:U.S.: 419-755-1280International: +1-419-755-1352For Canad
TABLE OF CONTENTS(continued)iiPUMP MAINTENANCE AND REPAIR - SECTION E PAGE E - 1...PERFORMANCE CURVE PAGE E - 1...
SUPER T SERIES OM-05444PAGE I - 1INTRODUCTIONINTRODUCTIONThank You for purchasing a Gorman‐Rupp pump.Read this manual carefully to learn how to safely
SUPER T SERIES OM-05444PAGE A - 1SAFETYSAFETY - SECTION AThis information applies to T Series basic pumps. Gorman‐Rupp has no control over or partic
SUPER T SERIESOM-05444PAGE A - 2 SAFETY1. Stop the pump immediately.2. Allow the pump to completely cool.3. Refer to instructions in this manualbefore
OM-05444SUPER T SERIESPAGE B - 1INSTALLATIONINSTALLATION - SECTION BReview all SAFETY information in Section A.Since pump installations are seldom ide
OM-05444 SUPER T SERIESPAGE B - 2 INSTALLATIONCheck that the pump shaft rotates counterclockwise when facing the impeller.Only operate this pump in