OM-06401-01February 15, 2011Rev. F 04‐23‐14ACDETHE GORMAN‐RUPP COMPANY MANSFIELD, OHIOwww.grpumps.comGORMAN‐RUPP OF CANADA LIMITED ST. THOMAS, ON
OM-06401 SF SERIESPAGE B - 2 INSTALLATIONSee Table B-1 for motor specifications.TABLE B-1. PUMP MOTOR SPECIFICATIONSMODEL VOLTAGE/PHASESIZE MOTORRPM
SF SERIES OM-06401PAGE B - 3INSTALLATIONMake certain that the pump and stand sit level inthe wet well.Regardless of the installation configuration, th
OM-06401 SF SERIESPAGE B - 4 INSTALLATIONMotor Cable Grounding TestDo not connect the pump power or control cables to the control box or incoming v
SF SERIES OM-06401PAGE B - 5INSTALLATIONdesirable, connect only to controls whichare wired for manual restart.Refer to the appropriate wiring diagram
SF SERIES OM-06401PAGE C - 1OPERATIONOPERATION - SECTION CGENERAL INFORMATIONReview all SAFETY information in Section A.This pump is designed to handl
OM-06401 SF SERIESPAGE C - 2 OPERATIONSFV4A 230/460/575V 3P PERFORMANCE CURVE
SF SERIES OM-06401PAGE C - 3OPERATIONSFV4A 208V 3P PERFORMANCE CURVE
OM-06401 SF SERIESPAGE C - 4 OPERATIONSFV4A 230V 1P PERFORMANCE CURVE
SF SERIES OM-06401PAGE C - 5OPERATIONControl BoxControl boxes are available as optional equipmentfrom the factory. The control boxes contain controls
OM-06401 SF SERIESPAGE C - 6 OPERATIONburns and injuries. If overheating of thepump occurs:1. Stop the pump immediately.2. Ventilate the area.3. Allow
Register your newGorman‐Rupp pump online atwww.grpumps.comValid serial number and e‐mail address required.RECORD YOUR PUMP MODEL AND SERIAL NUMBERPlea
SF SERIES OM-06401PAGE C - 7OPERATIONbetween starts, it will over‐heat, resulting indamage to the motor windings.StoppingFollow the instructions accom
OM-06401 SF SERIESPAGE C - 8 OPERATIONCheck the oil level(s) as indicated in the followingLUBRICATION section.COLD WEATHER PRESERVATIONDo not attempt
SF SERIES OM-06401PAGE C - 9OPERATIONin Draining Oil. Add premium quality submersiblepump oil through the fill plug hole until the oil is level with
TROUBLE POSSIBLE CAUSE PROBABLE REMEDYPUMP FAILS TOSTART, OVERLOADUNIT NOT TRIPPED(MANUAL MODE).Power source incompatible with control box.Correct po
TROUBLE POSSIBLE CAUSE PROBABLE REMEDYMOTOR RUNS, BUTPUMP FAILS TODELIVER RATEDDISCHARGE.Discharge head too high. Reduce discharge head or install
SF SERIES OM-06401PAGE D - 3TROUBLESHOOTINGELECTRICAL TESTINGMake the electrical checks which follow to determine if pump malfunctions are being caus
OM-06401 SF SERIESPAGE D - 4TROUBLESHOOTINGmotor cable green/yellow ground lead. Touchthe other test lead to each of the motor cableleads in turn. Not
OM-06401SF SERIESPAGE E - 1MAINTENANCE AND REPAIRPUMP MAINTENANCE AND REPAIR - SECTION EGENERAL INFORMATIONReview all SAFETY information in Section A.
SF SERIESOM-06401MAINTENANCE AND REPAIRPAGE E - 2ILLUSTRATIONPARTS PAGEFigure E-1. SFV4A Pump Model Assembly
ITEM NO.PART NAME PART NUMBERMAT'LCODEQTY ITEM NO.PART NAME PART NUMBERMAT'LCODEQTYOM-06401SF SERIESPAGE E - 3MAINTENANCE AND REPAIRSFV4A Pu
TABLE OF CONTENTSiINTRODUCTION PAGE I - 1...SAFETY ‐ SECTION A PAGE A - 1...
SF SERIESOM-06401MAINTENANCE AND REPAIRPAGE E - 4ILLUSTRATIONFigure E-2. 47111-803, -808, -809 and -857 Motor Assemblies
ITEM NO.PART NAME PART NUMBERMAT'LCODEQTY ITEM NO.PART NAME PART NUMBERMAT'LCODEQTYOM-06401SF SERIESPAGE E - 5MAINTENANCE AND REPAIR47111-80
SF SERIESOM-06401MAINTENANCE AND REPAIRPAGE E - 6PUMP AND SEAL DISASSEMBLY ANDREASSEMBLYReview all SAFETY information in Section A.This pump requires
OM-06401SF SERIESPAGE E - 7MAINTENANCE AND REPAIRwas faulty or questionable, the cause must be determined and corrected before reassembly. All O‐ring
SF SERIESOM-06401MAINTENANCE AND REPAIRPAGE E - 8Remove the impeller adjusting shims (19). Tie andtag the shims for ease of reassembly.If no further d
OM-06401SF SERIESPAGE E - 9MAINTENANCE AND REPAIRMost cleaning solvents are toxic andflammable. Use them only in a well ventilated area free from exc
SF SERIESOM-06401MAINTENANCE AND REPAIRPAGE E - 10Upper Seal Installation(Figures E-2 and E-3)Do not unwrap a new seal assembly until time ofinstallat
OM-06401SF SERIESPAGE E - 11MAINTENANCE AND REPAIRNOTEIf the seal plate was not removed during disassembly, cover the stationary element with a clean
SF SERIESOM-06401MAINTENANCE AND REPAIRPAGE E - 12tor be returned to Gorman‐Rupp, or to a Gorman‐Rupp authorized Submersible Repair Center.The electri
OM-06401SF SERIESPAGE E - 13MAINTENANCE AND REPAIRMost cleaning solvents are toxic andflammable. Use them only in a well ventilated area; free from e
TABLE OF CONTENTS(continued)iiPARTS LISTS:Pump Model Assembly PAGE E - 3...Motor Assemblies PAGE E - 5.
SF SERIESOM-06401MAINTENANCE AND REPAIRPAGE E - 14is strongly recommended that new O‐rings andshaft seal assemblies be used during reassembly(see the
OM-06401SF SERIESPAGE E - 15MAINTENANCE AND REPAIRthe intermediate until fully seated. If removed,install a new male terminal (15) on the sensor andpo
SF SERIESOM-06401MAINTENANCE AND REPAIRPAGE E - 16With the motor housing and stator positioned upside down, carefully lower the assembled intermedia
OM-06401SF SERIESPAGE E - 17MAINTENANCE AND REPAIRHoisting Bail Installation(Figure E-1)If the hoisting bail (13) was removed in order to remove the
SF SERIESOM-06401MAINTENANCE AND REPAIRPAGE E - 18ential between the vacuum readings shown in thetable.To vacuum test the motor cavity, the terminal h
OM-06401SF SERIESPAGE E - 19MAINTENANCE AND REPAIRThe grade of lubricant used is critical to the operation of this pump. Use premium quality hydrauli
For U.S. and International Warranty Information,Please Visit www.grpumps.com/warrantyor call:U.S.: 419-755-1280International: +1-419-755-1352For Canad
OM-06401SF SERIESPAGE I - 1INTRODUCTIONINTRODUCTIONThank You for purchasing a Gorman‐Rupp SF Series Pump. Read this manual carefully to learnhow to s
OM-06401SF SERIESPAGE A - 1SAFETYSAFETY - SECTION AThis information applies to the SF Series submersible pump indicated on thefront cover of this man
SF SERIESOM-06401PAGE A-2 SAFETYto the incoming power lines. The pumpmotor is designed to operate through aGorman‐Rupp approved control boxwhich provi
OM-06401SF SERIESPAGE A - 3SAFETYapproved by the manufacturer, can result in severe injury or death and voidwarranty.After the pump has been installe
SF SERIES OM-06401PAGE B - 1INSTALLATIONINSTALLATION - SECTION BReview all SAFETY information in Section A.Since pump installations are seldom identic