OM-00881-02 November 18, 2005ABCDETHE GORMAN-RUPP COMPANY D MANSFIELD, OHIOwww.gormanrupp.comGORMAN-RUPP OF CANADA LIMITED D ST. THOMAS, ONTARIO, CANA
80 SERIESOM−00881PAGE B − 4 INSTALLATIONsuction inlet at a distance 1-1/2 times the diameterof the suction pipe. The baffle will allow entrainedair to
80 SERIES OM−00881PAGE B − 5INSTALLATIONIf the application involves a high dischargehead, gradually close the dischargethrottling valve before stoppin
80 SERIESOM−00881PAGE B − 6 INSTALLATIONAir Release Valve InstallationThe Automatic Air Release Valve must be inde-pendently mounted in a horizontal p
80 SERIES OM−00881PAGE B − 7INSTALLATIONof the pump.When mounted at the Gorman-Rupp factory, driverand pump are aligned before shipment. Misalign-ment
80 SERIESOM−00881PAGE B − 8 INSTALLATIONbelts are a matched set; unmatched sets will causeaccelerated belt wear.MISALIGNED:SHAFTSNOT PARALLELMISALIGNE
OM−0088180 SERIESOPERATION PAGE C − 1OPERATION − SECTION CReview all SAFETY information in Section A.Follow the instructions on all tags, labels andde
OM−0088180 SERIESOPERATIONPAGE C − 2STARTINGConsult the operations manual furnished with thepower source.If the pump has been approved for use with pe
OM−0088180 SERIESOPERATION PAGE C − 3boil, build pressure, and cause the pump to rup-ture or explode. If overheating occurs, stop thepump and allow it
OM−0088180 SERIESOPERATIONPAGE C − 4curately by placing a contact-type thermometeragainst the housing. Record this temperature forfuture reference.A s
OM−0088180 SERIESTROUBLESHOOTING PAGE D − 1TROUBLESHOOTING − SECTION DReview all SAFETY information in Section A.Before attempting to open or service
TABLE OF CONTENTSiINTRODUCTION PAGE I − 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SAFETY - SE
OM−00881 80 SERIESTROUBLESHOOTINGPAGE D − 2TROUBLE POSSIBLE CAUSE PROBABLE REMEDYPUMP STOPS ORFAILS TO DELIVERRATED FLOW ORPRESSURE (cont.)PUMP REQUIR
OM−0088180 SERIESTROUBLESHOOTING PAGE D − 3PREVENTIVE MAINTENANCESince pump applications are seldom identical, andpump wear is directly affected by su
OM−0088180 SERIESMAINTENANCE & REPAIR PAGE E − 1PUMP MAINTENANCE AND REPAIR − SECTION EMAINTENANCE AND REPAIR OF THE WEARING PARTS OF THE PUMP WIL
OM−0088180 SERIESMAINTENANCE & REPAIRPAGE E − 2SECTION DRAWINGPARTS PAGEFigure 1. Pump Model 83A52−B
ITEM NO.PART NAME PART NUMBERMAT’LCODEQTY ITEM NO.PART NAME PART NUMBERMAT’LCODEQTYOM−0088180 SERIESMAINTENANCE & REPAIR PAGE E − 3PARTS LISTPump
OM−0088180 SERIESMAINTENANCE & REPAIRPAGE E − 4PUMP AND SEAL DISASSEMBLYAND REASSEMBLYReview all SAFETY information in Section A.Follow the instru
OM−0088180 SERIESMAINTENANCE & REPAIR PAGE E − 5Pump Casing RemovalTo service the impeller (2), wear plate assembly(34) and seal assembly (3), dis
OM−0088180 SERIESMAINTENANCE & REPAIRPAGE E − 6If no further disassembly is required, see SealReassembly and Installation.Shaft And Bearing Remova
OM−0088180 SERIESMAINTENANCE & REPAIR PAGE E − 7Replace the bearings, shaft, or pedestal if theproper bearing fit is not achieved.If bearing repla
OM−0088180 SERIESMAINTENANCE & REPAIRPAGE E − 8Install the slinger ring (27) and shaft key (20). Installany leveling shims used under the pedestal
TABLE OF CONTENTS(continued)iiTROUBLESHOOTING − SECTION D PAGE D − 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PREVENTIVE MAINTENANCE
OM−0088180 SERIESMAINTENANCE & REPAIR PAGE E − 9This seal is not designed for operation attemperatures above 160_F (71_C). Do notuse at higher ope
OM−0088180 SERIESMAINTENANCE & REPAIRPAGE E − 10Position the check valve assembly in the suctionport with the large weight (45) facing toward the
For U.S. and International Warranty Information,Please Visit www.grpumps.com/warrantyor call:U.S.: 419−755−1280International: +1−419−755−1352For Canad
80 SERIESOM−00881PAGE I − 1INTRODUCTIONINTRODUCTIONThank You for purchasing a Gorman-Rupp pump.Read this manual carefully to learn how to safelyinstal
80 SERIESOM−00881PAGE A − 1SAFETYSAFETY - SECTION AThis information applies to 80 Series ba-sic pumps. Gorman-Rupp has no con-trol over or particular
80 SERIESOM−00881PAGE A − 2 SAFETYunit and the National Electric Code orthe applicable local code, the Nationalor local code shall take precedence.If
80 SERIES OM−00881PAGE B − 1INSTALLATIONINSTALLATION − SECTION BReview all SAFETY information in Section A.Since pump installations are seldom identic
80 SERIESOM−00881PAGE B − 2 INSTALLATIONPREINSTALLATION INSPECTIONThe pump assembly was inspected and tested be-fore shipment from the factory. Befor
80 SERIES OM−00881PAGE B − 3INSTALLATIONcompatible with the liquid being pumped. If hose isused in suction lines, it must be the rigid-wall, rein-for